Back to Harry's Corner

Pacemaker Ventricular Block

Harry's Corner /

Fun with ECG’s

/

Pacemaker Ventricular Block

Author

Assoc Prof Harry Mond

Published

มีนาคม 3, 2025

Download a free PDF copy!

To receive a free PDF copy of The Fundamentals of Electrocardiograph Interpretation by Harry Mond, subscribe to his email blog by entering your email address below.  

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Purchase the textbook

Purchase a hard cover or paperback copy of The Fundamentals of Electrocardiograph Interpretation by Harry Mond on Amazon.

Purchase textbook

Last week, I showed this ECG which was interpreted as ventricular tachycardia with 3:2 Wenckebach block at the ectopic-myocardial junction.

I immediately had a number of emails, requesting evidence that such a block exists.

Here is a reference: Oreto G, Luzza F, Satullo G, Arrigo F.Non-sustained ventricular tachycardia with Wenckebach exit block. Journal of Electrocardiology 1987;20:51–4.

However, let us try and prove this for ourselves on the surface ECG!!

Is this possible? The answer is yes yes yes!

Think of the ectopic focus asa ventricular pacing stimulus artefact:

You can see the stimulus artefact (ectopic focus) on the surface ECG.

Following each stimulus artefact is a latency period between the stimulus artefact and the paced QRS(red highlight), which increases for each complex until there is exit block.

This is a 4:3 pacemaker Wenckebach exit block sequence in a dying heart at the stimulus artefact-myocardial junction.

I have called this type 1, second degree pacemaker-ventricular block.              

(Kistler, Mond and Vohra. Pacemaker Ventricular Block. PACE 2003: 23; 1997-1999).

‍

Definition:

A pacemaker-ventricular block is an altering temporal relationship between the stimulus artefact and the subsequent QRS.

So there must be a first degree pacemaker-ventricular block.

The latency is fixed (red highlight). We have previously seen this in the atrium.

(Someone will ask if pacemaker seconddegree block occurs in the atrium. I have never seen it, but here is a reference: Narula et al. B Heart J1972;34:1127).

 

What about type 2, second degree pacemaker-ventricular block?

There is latency, but alternate stimulus artefacts show exit block.

This could be type 1 or type 2, 2:1 pacemaker ventricular block!

 

As you would expect the mortality is very high and these tracings are usually immediately prior to death.

This case was an antidepressant overdose and the patient survived.  

Not all cases demonstrate latency.

Again this is in the patient with the dying heart.

‍

In summary:

The block is progressive until death, which is third degree pacemaker ventricular block, and this is where it all ends!!

Remember, it’s all in the timing.

Latest Articles

พฤศจิกายน 19, 2026

What Do You Think 126

I was asked for a second opinion on this Holter study as there was confusion with different QRS configurations and rhythms. I selected a bunch of strips. What do you think?

พฤศจิกายน 5, 2026

AV Node Reentry Tachycardia (AVNRT)

As its name implies, AVNRT is a reentrant junctional or supraventricular tachyarrhythmia which involves the fast and slow pathways within the AV node creating a self-perpetuating circus movement. It can be divided into typical (slow-fast) or atypical (fast-slow) as well as several rarer forms related to more than one slow or fast pathway with similar electrophysiological properties. On the ECG, they can be identified and differentiated by the positioning of the P wave in relation to the QRS complex, which in turn is related to the direction of the re-entrant AV nodal circuit. However, in about 60% of cases, the P wave is buried in the QRS/T and cannot be identified on the surface ECG.

ตุลาคม 16, 2026

Retrograde Conduction

Retrograde conduction is defined as conduction from an ectopic site to the atrium via the AV node or accessory pathway and referred to as VA conduction. II results in a P wave configuration which differs from an anterograde P wave, and in most ECG leads is inverted. The site from where the impulse originates can be the AV node, Bundle of His, distal conducting system or the body of the ventricles including ventricular pacing. On the ECG, the QRS complex usually precedes the inverted retrograde P wave but on occasion may follow it.