A Holter monitor I reported had Wenckebach AV block overnight.

Within a few minutes, there were two examples of two sequential dropped beats in the sequence (yellow highlight)

How would you interpret this and are they the same mechanism?
Look closely before you answer.
In Holter monitor reporting, the most common error by far is confusing Wenckebach AV block with non-conducted atrial ectopics.
To summarize:
Now let us return to our two dropped beats

The first is a Wenckebach AV sequence with a dropped beat (all sinus P waves red circles) followed by an atrial ectopic (blue circle) which does not conduct as conduction is still refractory. The next sinus beat (pale red circle) does not occur as the atrium is still refractory from the atrial ectopic (see Fun with ECGs 5).
The non-conducted atrial ectopic extends the Wenckebach AV pause.

In the second ECG, all the sinus P waves are present. The non-conducted atrial ectopic is very early and results in the next sinus P wave not conducting thus completing the sequence with a second dropped beat. The Wenckebach AV pause is not extended!
Its all in the timing!
November 19, 2026
I was asked for a second opinion on this Holter study as there was confusion with different QRS configurations and rhythms. I selected a bunch of strips. What do you think?
November 5, 2026
As its name implies, AVNRT is a reentrant junctional or supraventricular tachyarrhythmia which involves the fast and slow pathways within the AV node creating a self-perpetuating circus movement. It can be divided into typical (slow-fast) or atypical (fast-slow) as well as several rarer forms related to more than one slow or fast pathway with similar electrophysiological properties. On the ECG, they can be identified and differentiated by the positioning of the P wave in relation to the QRS complex, which in turn is related to the direction of the re-entrant AV nodal circuit. However, in about 60% of cases, the P wave is buried in the QRS/T and cannot be identified on the surface ECG.
October 16, 2026
Retrograde conduction is defined as conduction from an ectopic site to the atrium via the AV node or accessory pathway and referred to as VA conduction. II results in a P wave configuration which differs from an anterograde P wave, and in most ECG leads is inverted. The site from where the impulse originates can be the AV node, Bundle of His, distal conducting system or the body of the ventricles including ventricular pacing. On the ECG, the QRS complex usually precedes the inverted retrograde P wave but on occasion may follow it.